Facts:
· Weighing is made 10 times
per sec.
· The load cells are made of stainless steel
· +/- 1% exactness of quantity
The load cell system communicates with the electronic operating system of the spreader. At the least deviation the operating system sets the quantity by
CALIBRATOR ZURF. The load cell system weighs continuously the contents in the spreader and compares it with the driving speed and the required spread width.
M2W and M3W are equipped with 1 and 2 load cell(s), which are placed between the front frame and the 3-point linkage.
The weighing technique and BOGBALLE's operating systems mean FULLY automatic setting of quantity and 100% ground speed relation.